Power:
120/120 Plus:
Line voltages: 115 or 230 VAC
Frequency: 50 or 60 Hz
120 Plus:Â (estimated battery life)
60 hours with 1 x 350Ω, 40 hours with 4 x 350Ω
Charge time eight hoursExcitation Voltage:
5 VDC, 4 x 350Ω or 8 x 700Ω load cellsAnalog Signal Input Range:
-0.6 mV/V – 3.0 mV/VAnalog Signal Sensitivity:
0.3 μV/graduation minimum,
1.5 μV/grad recommendedA/D Sample Rate:
120:Â 3 to 30 Hz, software selectable
120 Plus:Â 30 Hz
Resolution:
Internal: 1 million internal graduations
Display: 10,000 displayed graduations
System Linearity:
Within 0.01% of full scale |
Circuit Protection:
RFI, EMI, ESD protectedLoad Cell Connection:
Cord grip entry
Detachable plug (optional)Serial Output:
EDP port: Full duplex RS-232
Printer port: Output-only RS-232 or active 20mA current loop
Both ports: 9600, 4800, 2400, 1200, 600, 300bps;
Seven or eight data bits; even, odd or no parityStatus Annunciators:
120/120 Plus:Â Center of zero, stand still, gross, net, lb, kg, oz, g
120 Plus:Â Battery, setpoint 1 and 2, HoldDisplay:
120:Â 0.8 in (20 mm), six-digit red light emitting diode
(LED) display, seven-segment digits
120 Plus:Â 0.8 in (20 mm) six-digit LCD with backlight, seven-segment digits
Keys/Buttons:
120:Â Five-key flat membrane panel, tactile feel
120 Plus:Â Zero, tare, preset tare, hold, gross/net, units, numeric 0-9, clear, enter/print |
(Optional) Digital I/O:
120 Plus:Â Requires option card
24 volt source
Three digital inputs
Two digital outputsTemperature Range:
Certified: 14°F to 104°F (-10°C to 40°C)
Operating: 14°F to 122°F (-10°C to 50°C)Rating/Material:
Enclosure: heavy gauge ABSWeight:
2.6 lb (1.2 kg)Warranty:
One-year limited warranty
Approvals:
NTEP CC 03-059, Class III/IIIL 10,000d
Measurement Canada AM-5517, Class III/IIIHD 10,000d
EU Test Certificate TC7028 (120) Class III, 10,000d
EU Test Certificate TC7626 (120 Plus) Class III, 10,000d
CE marked |